The structural question
Navier needed to determine whether the existing hydrofoil appendages could support an increased payload requirement.
The assembly combines foils approximately 1.5 m wide with struts approximately 2 m long, so deformation and load transfer had to be assessed at assembly level.
What I did
- Prepared and ran nonlinear structural models in 3DEXPERIENCE.
- Analysed the foil, strut and mechanical interfaces as a complete assembly.
- Evaluated stiffness, deformation and composite response.
- Checked sensitivity to geometry, laminate properties, applied loads and boundary conditions.
- Interpreted the results to support the retain-or-redesign decision.
Analysis approach
Geometry
Modelled the structural form and interfaces governing assembly stiffness.
Composite definition
Used laminate properties and orientations to assess stiffness and structural response.
Load introduction
Applied loads through the foil, strut and connections.
Boundary conditions
Matched the constraints to the physical support of the assembly.
Outcome
The analysis supported retaining the existing appendage design for the increased payload requirement.